build/dts/api/bindings/sensor/nordic,npm1300-charger.html · build/dts/api/bindings/sensor/nordic,npm1300-charger.rst 공식 원문 ↗

Zephyr 3.7.0 · Devicetree · Sensor · Nordic Semiconductor

Nordic nPM1300 PMIC Charger 바인딩

nPM1300의 충전·방전·VBUS 제한, thermistor 보호와 recharge/die-temperature 정책를 정의하는 43개 property schema입니다.

Official pathbuild/dts/api/bindings/sensor/nordic,npm1300-charger.html
Source filebuild/dts/api/bindings/sensor/nordic,npm1300-charger.rst
Source versionZephyr 3.7.0
TranslationFull · reviewed

본문 기준: Zephyr 3.7.0 LTS3 · 이후 유지보수 패치는 별도입니다.

Part 1

요약·해설

공식 원문 453줄과 property 43행을 전수 대조해 five required charger and thermistor values·microvolt/microamp/millidegree units·hardware-step rounding·warm fallback·trickle and termination defaults·thermal stop/resume policy 제약을 보존했습니다.

Compatible

nordic,npm1300-charger

Vendor

Nordic Semiconductor

Properties

43 rows

Interface

PMIC battery charger configuration and telemetry

Part 2

접을 수 있는 영어 원문 전체

영어 원문 전체 펼치기
원문 SHA-256 86A9331CF2999C41D56EC99DF4B146C8292EA04B7FB533A7764B9734D2B75632
:orphan:

.. raw:: html

    <!--
    FIXME: do not limit page width until content uses another representation
    format other than tables
    -->
    <style>.wy-nav-content { max-width: none; !important }</style>

.. dtcompatible:: nordic,npm1300-charger
.. _dtbinding_nordic_npm1300_charger:

nordic,npm1300-charger
######################

Vendor: :ref:`Nordic Semiconductor <dt_vendor_nordic>`

Description
***********



.. code-block:: none

   NPM1300 PMIC Charger

Properties
**********

.. tabs::

   .. group-tab:: Node specific properties

      Properties not inherited from the base binding file.

      .. list-table::
         :widths: 1 1 4
         :header-rows: 1

         * - Name
           - Type
           - Details

         * - ``friendly-name``
           - ``string``
           - .. code-block:: none

                Human readable string describing the sensor. It can be used to
                distinguish multiple instances of the same model (e.g., lid accelerometer
                vs. base accelerometer in a laptop) to a host operating system.

                This property is defined in the Generic Sensor Property Usages of the HID
                Usage Tables specification
                (https://usb.org/sites/default/files/hut1_3_0.pdf, section 22.5).



         * - ``term-microvolt``
           - ``int``
           - .. code-block:: none

                Charge termination voltage in uV.
                Available range is 3.5 V to 3.65 V and 4.0 V to 4.45 V in 50 mV steps.



             This property is **required**.

         * - ``term-warm-microvolt``
           - ``int``
           - .. code-block:: none

                Charge termination voltage when warm in uV.
                Available range is 3.5 V to 3.65 V and 4.0 V to 4.45 V in 50 mV steps.
                If omitted, the term-microvolt value will be used.



         * - ``current-microamp``
           - ``int``
           - .. code-block:: none

                Charge current in uA.
                Available range is 32 mA to 800 mA in 2mA steps.
                The value specified will be rounded down to the closest implemented value.



             This property is **required**.

         * - ``dischg-limit-microamp``
           - ``int``
           - .. code-block:: none

                Discharge current limit in uA.
                Available range is 270 mA to 1340 mA in 3.23 mA steps.
                The value specified will be rounded down to the closest implemented value.



             This property is **required**.

         * - ``vbus-limit-microamp``
           - ``int``
           - .. code-block:: none

                Vbus current limit in uA.
                Available values are 100 mA, or between 500 mA and 1500 mA in 100 mA steps.
                If omitted, the default value of 100 mA will be used.



         * - ``thermistor-ohms``
           - ``int``
           - .. code-block:: none

                Thermistor nominal resistance type in ohms.


             This property is **required**.

             Legal values: ``10000``, ``47000``, ``100000``

         * - ``thermistor-beta``
           - ``int``
           - .. code-block:: none

                Beta value of selected thermistor.


             This property is **required**.

         * - ``thermistor-cold-millidegrees``
           - ``int``
           - .. code-block:: none

                Thermistor cold threshold in milli-degrees


         * - ``thermistor-cool-millidegrees``
           - ``int``
           - .. code-block:: none

                Thermistor cool threshold in milli-degrees


         * - ``thermistor-warm-millidegrees``
           - ``int``
           - .. code-block:: none

                Thermistor warm threshold in milli-degrees


         * - ``thermistor-hot-millidegrees``
           - ``int``
           - .. code-block:: none

                Thermistor hot threshold in milli-degrees


         * - ``charging-enable``
           - ``boolean``
           - .. code-block:: none

                Enable charging.



         * - ``trickle-microvolt``
           - ``int``
           - .. code-block:: none

                Trickle voltage threshold in uV.
                Trickle charging is enabled below this value.
                If omitted the device default of 2.9V is used.



             Default value: ``2900000``

             Legal values: ``2900000``, ``2500000``

         * - ``term-current-percent``
           - ``int``
           - .. code-block:: none

                Termination current, as a percentage of current-microamp.
                Charge completes when the charge current falls below this value.
                If omitted the device default of 10% is used.



             Default value: ``10``

             Legal values: ``10``, ``20``

         * - ``vbatlow-charge-enable``
           - ``boolean``
           - .. code-block:: none

                Allow charging when below the vbatlow threshold.



         * - ``disable-recharge``
           - ``boolean``
           - .. code-block:: none

                Disable automatic recharge.



         * - ``dietemp-stop-millidegrees``
           - ``int``
           - .. code-block:: none

                Die temperature halt threshold in milli-degrees.
                When die temperature exceeds this threshold, charging will be inhibited.



         * - ``dietemp-resume-millidegrees``
           - ``int``
           - .. code-block:: none

                Die temperature resume threshold in milli-degrees.
                When die temperature falls below this threshold, charging will be permitted.





   .. group-tab:: Deprecated node specific properties

      Deprecated properties not inherited from the base binding file.

      (None)

   .. group-tab:: Base properties

      Properties inherited from the base binding file, which defines
      common properties that may be set on many nodes. Not all of these
      may apply to the "nordic,npm1300-charger" compatible.

      .. list-table::
         :widths: 1 1 4
         :header-rows: 1

         * - Name
           - Type
           - Details

         * - ``wakeup-source``
           - ``boolean``
           - .. code-block:: none

                Property to identify that a device can be used as wake up source.

                When this property is provided a specific flag is set into the
                device that tells the system that the device is capable of
                wake up the system.

                Wake up capable devices are disabled (interruptions will not wake up
                the system) by default but they can be enabled at runtime if necessary.



         * - ``power-domain``
           - ``phandle``
           - .. code-block:: none


                Power domain the device belongs to.

                The device will be notified when the power domain it belongs to is either
                suspended or resumed.



         * - ``zephyr,pm-device-runtime-auto``
           - ``boolean``
           - .. code-block:: none

                Automatically configure the device for runtime power management after the
                init function runs.



         * - ``zephyr,disabling-power-states``
           - ``phandles``
           - .. code-block:: none

                List of power states that will disable this device power.



         * - ``status``
           - ``string``
           - .. code-block:: none

                indicates the operational status of a device


             Legal values: ``'ok'``, ``'okay'``, ``'disabled'``, ``'reserved'``, ``'fail'``, ``'fail-sss'``

             See :ref:`dt-important-props` for more information.

         * - ``compatible``
           - ``string-array``
           - .. code-block:: none

                compatible strings


             This property is **required**.

             See :ref:`dt-important-props` for more information.

         * - ``reg``
           - ``array``
           - .. code-block:: none

                register space


             See :ref:`dt-important-props` for more information.

         * - ``reg-names``
           - ``string-array``
           - .. code-block:: none

                name of each register space


         * - ``interrupts``
           - ``array``
           - .. code-block:: none

                interrupts for device


             See :ref:`dt-important-props` for more information.

         * - ``interrupts-extended``
           - ``compound``
           - .. code-block:: none

                extended interrupt specifier for device


         * - ``interrupt-names``
           - ``string-array``
           - .. code-block:: none

                name of each interrupt


         * - ``interrupt-parent``
           - ``phandle``
           - .. code-block:: none

                phandle to interrupt controller node


         * - ``label``
           - ``string``
           - .. code-block:: none

                Human readable string describing the device (used as device_get_binding() argument)



             See :ref:`dt-important-props` for more information.

             This property is **deprecated**.

         * - ``clocks``
           - ``phandle-array``
           - .. code-block:: none

                Clock gate information


         * - ``clock-names``
           - ``string-array``
           - .. code-block:: none

                name of each clock


         * - ``#address-cells``
           - ``int``
           - .. code-block:: none

                number of address cells in reg property


         * - ``#size-cells``
           - ``int``
           - .. code-block:: none

                number of size cells in reg property


         * - ``dmas``
           - ``phandle-array``
           - .. code-block:: none

                DMA channels specifiers


         * - ``dma-names``
           - ``string-array``
           - .. code-block:: none

                Provided names of DMA channel specifiers


         * - ``io-channels``
           - ``phandle-array``
           - .. code-block:: none

                IO channels specifiers


         * - ``io-channel-names``
           - ``string-array``
           - .. code-block:: none

                Provided names of IO channel specifiers


         * - ``mboxes``
           - ``phandle-array``
           - .. code-block:: none

                mailbox / IPM channels specifiers


         * - ``mbox-names``
           - ``string-array``
           - .. code-block:: none

                Provided names of mailbox / IPM channel specifiers


         * - ``zephyr,deferred-init``
           - ``boolean``
           - .. code-block:: none

                Do not initialize device automatically on boot. Device should be manually
                initialized using device_init().






Part 3

한국어 전문 번역

nordic,npm1300-charger

Vendor: Nordic Semiconductor

공식 설명

NPM1300 PMIC Charger

충전 전류·전압과 battery thermal policy를 한 schema로 고정

term-microvolt, current-microamp, dischg-limit-microamp, thermistor-ohms, thermistor-beta, base compatible가 필수입니다.

Charge profile

Termination voltage + charge current

Current limits

Discharge + VBUS

Battery thermistor

Resistance · beta · 4 thresholds

Safety policy

Die stop/resume · recharge

충전 전류는 2mA step, 방전 제한은 3.23mA step의 가장 가까운 하위 구현값으로 내림합니다. 단위가 property 이름에서는 uA여도 공식 범위 설명은 mA입니다.

term-warm-microvolt는 생략 시 일반 종료 전압을 사용합니다. vbus-limit-microamp의 100mA는 설명 속 fallback이며 formal Default value 행은 없습니다.

trickle-microvolt 기본값은 2900000, term-current-percent 기본값은 10입니다. Thermal threshold와 charging boolean은 선택입니다.

속성 전체 번역

공식 node-specific 19개와 base 24개 property를 모두 번역했습니다.

노드 전용 속성 · 19개
이름형식설명과 제약
friendly-namestring호스트 운영체제가 같은 모델의 센서 여러 개를 구분할 때 쓰는 이름입니다. HID Usage Tables 1.3의 22.5절에 정의되어 있습니다.
term-microvoltint충전 종료 전압(uV)입니다. 3.5~3.65V와 4.0~4.45V 구간에서 50mV step을 사용합니다.
필수
term-warm-microvoltintWarm 상태의 충전 종료 전압(uV)입니다. 생략하면 term-microvolt를 사용합니다.
current-microampint충전 전류(uA)입니다. 32~800mA 범위를 2mA step으로 구현하며 지정값을 가장 가까운 하위 구현값으로 내림합니다.
필수
dischg-limit-microampint방전 전류 제한(uA)입니다. 270~1340mA 범위를 3.23mA step으로 구현하며 지정값을 하위 구현값으로 내림합니다.
필수
vbus-limit-microampintVBUS 전류 제한(uA)입니다. 100mA 또는 500~1500mA의 100mA step이며 생략 시 100mA를 사용합니다.
thermistor-ohmsintThermistor nominal resistance(ohm)입니다. 10000·47000·100000 중 하나가 필수입니다.
필수 · 허용값: 10000, 47000, 100000
thermistor-betaint선택한 thermistor의 beta 값이며 필수입니다.
필수
thermistor-cold-millidegreesintThermistor cold threshold이며 milli-degree 단위입니다.
thermistor-cool-millidegreesintThermistor cool threshold이며 milli-degree 단위입니다.
thermistor-warm-millidegreesintThermistor warm threshold이며 milli-degree 단위입니다.
thermistor-hot-millidegreesintThermistor hot threshold이며 milli-degree 단위입니다.
charging-enableboolean설정하면 charging을 활성화합니다.
trickle-microvoltintTrickle charging을 시작하는 전압 threshold(uV)입니다. 기본값 2900000이고 2900000·2500000 중 선택합니다.
기본값: 2900000 · 허용값: 2900000, 2500000
term-current-percentintcurrent-microamp 대비 종료 전류 비율입니다. 충전 전류가 이 값 아래로 떨어지면 완료되며 기본 10%, legal 값은 10·20입니다.
기본값: 10 · 허용값: 10, 20
vbatlow-charge-enableboolean설정하면 vbatlow threshold 아래에서도 charging을 허용합니다.
disable-rechargeboolean설정하면 automatic recharge를 비활성화합니다.
dietemp-stop-millidegreesintCharging을 중단할 die temperature threshold이며 milli-degree 단위입니다.
dietemp-resume-millidegreesintCharging을 재개할 die temperature threshold이며 milli-degree 단위입니다.
Base binding property · 24개

공통 기본 바인딩에서 상속한 속성입니다. 이 compatible에서 사용하지 않는 속성도 공식 참조 문서에 실려 있으면 함께 표시합니다.

이름형식설명과 제약
wakeup-sourceboolean이 장치를 시스템 깨우기에 사용할 수 있음을 나타냅니다. 이 속성이 있으면 깨우기 지원 플래그가 설정됩니다. 기본 상태에서는 장치의 인터럽트로 시스템을 깨우지 않으며, 실행 중에 깨우기 기능을 활성화할 수 있습니다.
power-domainphandle장치가 속한 전원 도메인의 phandle입니다. 해당 전원 도메인이 일시 중단되거나 다시 동작하면 장치에 알림이 전달됩니다.
zephyr,pm-device-runtime-autoboolean초기화 함수 실행 후 장치의 런타임 전원 관리를 자동으로 설정합니다.
zephyr,disabling-power-statesphandles이 장치의 전원이 꺼지는 전원 상태 목록입니다.
statusstring장치의 동작 상태를 나타냅니다.
허용값: 'ok', 'okay', 'disabled', 'reserved', 'fail', 'fail-sss'
compatiblestring-array이 노드에 적용할 바인딩과 드라이버를 식별하는 compatible 문자열 목록입니다.
필수
regarray장치 레지스터의 주소 범위를 지정합니다.
reg-namesstring-array각 register space의 이름입니다.
interruptsarray장치에서 사용하는 인터럽트를 지정하는 목록입니다.
interrupts-extendedcompound인터럽트 컨트롤러의 phandle을 함께 지정하는 확장 형식의 인터럽트 명세입니다.
interrupt-namesstring-array각 interrupt의 이름입니다.
interrupt-parentphandle인터럽트 컨트롤러 노드를 가리키는 phandle입니다.
labelstring사람이 장치를 알아볼 수 있도록 붙이는 이름입니다. 과거에는 device_get_binding()의 인자로 사용했습니다.
사용 중단됨
clocksphandle-array클록 게이트 또는 클록 공급원을 지정하는 phandle 배열입니다.
clock-namesstring-array각 clock의 이름입니다.
#address-cellsint하위 노드의 reg 속성에서 주소를 나타내는 데 쓰는 셀 수입니다.
#size-cellsint하위 노드의 reg 속성에서 크기를 나타내는 데 쓰는 셀 수입니다.
dmasphandle-arrayDMA 채널을 지정하는 phandle 배열입니다.
dma-namesstring-array지정한 DMA 채널의 이름입니다.
io-channelsphandle-arrayI/O 채널을 지정하는 phandle 배열입니다.
io-channel-namesstring-array지정한 I/O 채널의 이름입니다.
mboxesphandle-array메일박스/IPM 채널을 지정하는 phandle 배열입니다.
mbox-namesstring-array지정한 메일박스/IPM 채널의 이름입니다.
zephyr,deferred-initboolean부팅할 때 장치를 자동으로 초기화하지 않습니다. 이후 device_init()를 호출해 직접 초기화해야 합니다.

Source

출처

영어 원문에는 문단, 문서 지시문, 표, 코드, 코드 심벌, 경로를 그대로 보존했습니다.