build/dts/api/bindings/i3c/nuvoton,npcx-i3c.html · build/dts/api/bindings/i3c/nuvoton,npcx-i3c.rst 공식 원문 ↗

Zephyr 3.7.0 · Devicetree · I3C · Nuvoton Technology Corporation

Nuvoton NPCX I3C Controller 바인딩

NPCX I3C의 push-pull·open-drain clock과 reset를 정의하는 35개 property schema입니다.

Official pathbuild/dts/api/bindings/i3c/nuvoton,npcx-i3c.html
Source filebuild/dts/api/bindings/i3c/nuvoton,npcx-i3c.rst
Source versionZephyr 3.7.0
TranslationFull · reviewed

본문 기준: Zephyr 3.7.0 LTS3 · 이후 유지보수 패치는 별도입니다.

Part 1

요약·해설

공식 원문 398줄과 property 35행을 전수 대조해 required reset·separate PP/OD clock suggestions·3-cell child addressing 제약을 보존했습니다.

Compatible

nuvoton,npcx-i3c

Vendor

Nuvoton Technology Corporation

Properties

35 rows

Interface

NPCX mixed I3C/I2C + reset + optional pin states

Part 2

접을 수 있는 영어 원문 전체

영어 원문 전체 펼치기
원문 SHA-256 730357BC53DD60D8030780F8C8242DA68E31AD850BA3C9FA6E15FF0CBDCBBC63
:orphan:

.. raw:: html

    <!--
    FIXME: do not limit page width until content uses another representation
    format other than tables
    -->
    <style>.wy-nav-content { max-width: none; !important }</style>

.. dtcompatible:: nuvoton,npcx-i3c
.. _dtbinding_nuvoton_npcx_i3c:

nuvoton,npcx-i3c
################

Vendor: :ref:`Nuvoton Technology Corporation <dt_vendor_nuvoton>`

Description
***********

These nodes are "['i3c', 'i2c']" bus nodes.

.. code-block:: none

   Nuvoton I3C controller

   Representation:

   /* If CONFIG_I3C_NPCX is enabled, the suggested clock configuration is as follows: */
   &pcc {
     clock-frequency = <DT_FREQ_M(90)>; /* OFMCLK runs at 90MHz */
     core-prescaler = <3>; /* CORE_CLK runs at 30MHz */
     apb1-prescaler = <6>; /* APB1_CLK runs at 15MHz */
     apb2-prescaler = <6>; /* APB2_CLK runs at 15MHz */
     apb3-prescaler = <6>; /* APB3_CLK runs at 15MHz */
     apb4-prescaler = <3>; /* APB4_CLK runs at 30MHz */
   };

   &rst {
     status = "okay";
   };

   &i3c0 {
     status = "okay";

     /* I3C clock frequency suggestion = <PP_SCL, OD_SCL> */
      * Full speed = <12500000, 4170000>
      * Normal speed = <7500000, 1500000>
      */
     i3c-scl-hz = <12500000>;
     i3c-od-scl-hz = <4170000>;
   };

Properties
**********

.. tabs::

   .. group-tab:: Node specific properties

      Properties not inherited from the base binding file.

      .. list-table::
         :widths: 1 1 4
         :header-rows: 1

         * - Name
           - Type
           - Details

         * - ``i3c-scl-hz``
           - ``int``
           - .. code-block:: none

                Frequency of the SCL signal used for I3C transfers. When undefined,
                use the controller default or as specified by the I3C specification.



         * - ``i2c-scl-hz``
           - ``int``
           - .. code-block:: none

                Frequency of the SCL signal used for I2C transfers. When undefined
                and there are I2C devices attached to the bus, look at the Legacy
                Virtual Register (LVR) of all connected I2C devices to determine
                the maximum allowed frequency.



         * - ``pinctrl-0``
           - ``phandles``
           - .. code-block:: none

                Pin configuration/s for the first state. Content is specific to the
                selected pin controller driver implementation.



         * - ``pinctrl-1``
           - ``phandles``
           - .. code-block:: none

                Pin configuration/s for the second state. See pinctrl-0.



         * - ``pinctrl-2``
           - ``phandles``
           - .. code-block:: none

                Pin configuration/s for the third state. See pinctrl-0.



         * - ``pinctrl-3``
           - ``phandles``
           - .. code-block:: none

                Pin configuration/s for the fourth state. See pinctrl-0.



         * - ``pinctrl-4``
           - ``phandles``
           - .. code-block:: none

                Pin configuration/s for the fifth state. See pinctrl-0.



         * - ``pinctrl-names``
           - ``string-array``
           - .. code-block:: none

                Names for the provided states. The number of names needs to match the
                number of states.



         * - ``resets``
           - ``phandle-array``
           - .. code-block:: none

                Reset information


             This property is **required**.

         * - ``reset-names``
           - ``string-array``
           - .. code-block:: none

                Name of each reset


         * - ``i3c-od-scl-hz``
           - ``int``
           - .. code-block:: none

                Open Drain Frequency for the I3C controller. When undefined, use
                the controller default or as specified by the I3C specification.





   .. group-tab:: Deprecated node specific properties

      Deprecated properties not inherited from the base binding file.

      (None)

   .. group-tab:: Base properties

      Properties inherited from the base binding file, which defines
      common properties that may be set on many nodes. Not all of these
      may apply to the "nuvoton,npcx-i3c" compatible.

      .. list-table::
         :widths: 1 1 4
         :header-rows: 1

         * - Name
           - Type
           - Details

         * - ``wakeup-source``
           - ``boolean``
           - .. code-block:: none

                Property to identify that a device can be used as wake up source.

                When this property is provided a specific flag is set into the
                device that tells the system that the device is capable of
                wake up the system.

                Wake up capable devices are disabled (interruptions will not wake up
                the system) by default but they can be enabled at runtime if necessary.



         * - ``power-domain``
           - ``phandle``
           - .. code-block:: none


                Power domain the device belongs to.

                The device will be notified when the power domain it belongs to is either
                suspended or resumed.



         * - ``zephyr,pm-device-runtime-auto``
           - ``boolean``
           - .. code-block:: none

                Automatically configure the device for runtime power management after the
                init function runs.



         * - ``zephyr,disabling-power-states``
           - ``phandles``
           - .. code-block:: none

                List of power states that will disable this device power.



         * - ``status``
           - ``string``
           - .. code-block:: none

                indicates the operational status of a device


             Legal values: ``'ok'``, ``'okay'``, ``'disabled'``, ``'reserved'``, ``'fail'``, ``'fail-sss'``

             See :ref:`dt-important-props` for more information.

         * - ``compatible``
           - ``string-array``
           - .. code-block:: none

                compatible strings


             This property is **required**.

             See :ref:`dt-important-props` for more information.

         * - ``reg``
           - ``array``
           - .. code-block:: none

                register space


             This property is **required**.

             See :ref:`dt-important-props` for more information.

         * - ``reg-names``
           - ``string-array``
           - .. code-block:: none

                name of each register space


         * - ``interrupts``
           - ``array``
           - .. code-block:: none

                interrupts for device


             This property is **required**.

             See :ref:`dt-important-props` for more information.

         * - ``interrupts-extended``
           - ``compound``
           - .. code-block:: none

                extended interrupt specifier for device


         * - ``interrupt-names``
           - ``string-array``
           - .. code-block:: none

                name of each interrupt


         * - ``interrupt-parent``
           - ``phandle``
           - .. code-block:: none

                phandle to interrupt controller node


         * - ``label``
           - ``string``
           - .. code-block:: none

                Human readable string describing the device (used as device_get_binding() argument)



             See :ref:`dt-important-props` for more information.

             This property is **deprecated**.

         * - ``clocks``
           - ``phandle-array``
           - .. code-block:: none

                Clock gate information


         * - ``clock-names``
           - ``string-array``
           - .. code-block:: none

                name of each clock


         * - ``#address-cells``
           - ``int``
           - .. code-block:: none

                number of address cells in reg property


             This property is **required**.

             Constant value: ``3``

         * - ``#size-cells``
           - ``int``
           - .. code-block:: none

                number of size cells in reg property


             This property is **required**.

         * - ``dmas``
           - ``phandle-array``
           - .. code-block:: none

                DMA channels specifiers


         * - ``dma-names``
           - ``string-array``
           - .. code-block:: none

                Provided names of DMA channel specifiers


         * - ``io-channels``
           - ``phandle-array``
           - .. code-block:: none

                IO channels specifiers


         * - ``io-channel-names``
           - ``string-array``
           - .. code-block:: none

                Provided names of IO channel specifiers


         * - ``mboxes``
           - ``phandle-array``
           - .. code-block:: none

                mailbox / IPM channels specifiers


         * - ``mbox-names``
           - ``string-array``
           - .. code-block:: none

                Provided names of mailbox / IPM channel specifiers


         * - ``zephyr,deferred-init``
           - ``boolean``
           - .. code-block:: none

                Do not initialize device automatically on boot. Device should be manually
                initialized using device_init().






Part 3

한국어 전문 번역

nuvoton,npcx-i3c

Vendor: Nuvoton Technology Corporation

공식 설명

These nodes are "['i3c', 'i2c']" bus nodes.


Nuvoton I3C controller

Representation:

/* If CONFIG_I3C_NPCX is enabled, the suggested clock configuration is as follows: */
&pcc {
  clock-frequency = <DT_FREQ_M(90)>; /* OFMCLK runs at 90MHz */
  core-prescaler = <3>; /* CORE_CLK runs at 30MHz */
  apb1-prescaler = <6>; /* APB1_CLK runs at 15MHz */
  apb2-prescaler = <6>; /* APB2_CLK runs at 15MHz */
  apb3-prescaler = <6>; /* APB3_CLK runs at 15MHz */
  apb4-prescaler = <3>; /* APB4_CLK runs at 30MHz */
};

&rst {
  status = "okay";
};

&i3c0 {
  status = "okay";

  /* I3C clock frequency suggestion = <PP_SCL, OD_SCL> */
   * Full speed = <12500000, 4170000>
   * Normal speed = <7500000, 1500000>
   */
  i3c-scl-hz = <12500000>;
  i3c-od-scl-hz = <4170000>;
};

Nuvoton NPCX I3C

i3c-scl-hz는 I3C transfer SCL, i2c-scl-hz는 legacy I2C transfer SCL입니다. I3C 값은 생략 시 controller 기본값 또는 specification을 따르고, I2C 값은 생략 시 연결된 I2C device의 LVR을 확인해 허용 frequency를 정합니다.

i3c-od-scl-hz는 open-drain 구간의 별도 frequency이며 생략 시 controller 기본값 또는 I3C specification을 따릅니다. 최대 다섯 pinctrl state와 이름은 선택이고 resets만 node-specific 필수값입니다. reset-names는 선택입니다.

공식 clock configuration 예

OFMCLK = 90 MHz
CORE_CLK = 30 MHz  (core-prescaler = 3)
APB1/2/3 = 15 MHz (prescaler = 6)
APB4 = 30 MHz     (prescaler = 3)
i3c-scl-hz = 12500000
i3c-od-scl-hz = 4170000

원문은 이를 full-speed 권장 예로 제시하며 normal-speed 예는 7,500,000 Hz와 1,500,000 Hz입니다. 이 숫자를 모든 NPCX system의 고정값으로 바꾸지 않았습니다.

Base compatible·reg·interrupts·#address-cells·#size-cells가 필수이고 clock phandle과 DMA는 선택입니다.

Base #address-cells와 #size-cells가 필수이고 I3C child address를 위해 #address-cells는 3으로 고정됩니다.

속성 전체 번역

공식 node 11개와 base 24개 property를 모두 번역했습니다.

노드 전용 속성 · 11개
이름형식설명과 제약
i3c-scl-hzintI3C transfer에 사용할 SCL frequency입니다. 생략하면 controller 기본값 또는 I3C specification 값을 사용합니다.
i2c-scl-hzintI2C transfer용 SCL frequency입니다. 생략하고 I2C device가 연결돼 있으면 모든 device의 LVR을 확인해 허용 가능한 최대 frequency를 정합니다.
pinctrl-0phandles첫 번째 상태에서 사용할 핀 설정입니다. 구체적인 내용은 선택한 핀 컨트롤러 드라이버에 따라 달라집니다.
pinctrl-1phandles두 번째 상태에서 사용할 핀 설정입니다. pinctrl-0과 같은 형식입니다.
pinctrl-2phandles세 번째 상태에서 사용할 핀 설정입니다. pinctrl-0과 같은 형식입니다.
pinctrl-3phandles네 번째 상태에서 사용할 핀 설정입니다. pinctrl-0과 같은 형식입니다.
pinctrl-4phandles다섯 번째 상태에서 사용할 핀 설정입니다. pinctrl-0과 같은 형식입니다.
pinctrl-namesstring-array핀 설정 상태의 이름입니다. 이름 수는 정의한 상태 수와 같아야 합니다.
resetsphandle-arrayController reset specifier를 담는 phandle array입니다.
필수
reset-namesstring-array각 reset specifier에 대응하는 이름입니다.
i3c-od-scl-hzintI3C controller가 open-drain 구간에서 사용할 SCL frequency입니다. 생략하면 controller 기본값 또는 I3C specification 값을 사용합니다.
Base binding property · 24개

공통 기본 바인딩에서 상속한 속성입니다. 이 compatible에서 사용하지 않는 속성도 공식 참조 문서에 실려 있으면 함께 표시합니다.

이름형식설명과 제약
wakeup-sourceboolean이 장치를 시스템 깨우기에 사용할 수 있음을 나타냅니다. 이 속성이 있으면 깨우기 지원 플래그가 설정됩니다. 기본 상태에서는 장치의 인터럽트로 시스템을 깨우지 않으며, 실행 중에 깨우기 기능을 활성화할 수 있습니다.
power-domainphandle장치가 속한 전원 도메인의 phandle입니다. 해당 전원 도메인이 일시 중단되거나 다시 동작하면 장치에 알림이 전달됩니다.
zephyr,pm-device-runtime-autoboolean초기화 함수 실행 후 장치의 런타임 전원 관리를 자동으로 설정합니다.
zephyr,disabling-power-statesphandles이 장치의 전원이 꺼지는 전원 상태 목록입니다.
statusstring장치의 동작 상태를 나타냅니다.
허용값: 'ok', 'okay', 'disabled', 'reserved', 'fail', 'fail-sss'
compatiblestring-array이 노드에 적용할 바인딩과 드라이버를 식별하는 compatible 문자열 목록입니다.
필수
regarray장치 레지스터의 주소 범위를 지정합니다.
필수
reg-namesstring-array각 register space의 이름입니다.
interruptsarray장치에서 사용하는 인터럽트를 지정하는 목록입니다.
필수
interrupts-extendedcompound인터럽트 컨트롤러의 phandle을 함께 지정하는 확장 형식의 인터럽트 명세입니다.
interrupt-namesstring-array각 interrupt의 이름입니다.
interrupt-parentphandle인터럽트 컨트롤러 노드를 가리키는 phandle입니다.
labelstring사람이 장치를 알아볼 수 있도록 붙이는 이름입니다. 과거에는 device_get_binding()의 인자로 사용했습니다.
사용 중단됨
clocksphandle-array클록 게이트 또는 클록 공급원을 지정하는 phandle 배열입니다.
clock-namesstring-array각 clock의 이름입니다.
#address-cellsint하위 노드의 reg 속성에서 주소를 나타내는 데 쓰는 셀 수입니다.
필수 · 고정값: 3
#size-cellsint하위 노드의 reg 속성에서 크기를 나타내는 데 쓰는 셀 수입니다.
필수
dmasphandle-arrayDMA 채널을 지정하는 phandle 배열입니다.
dma-namesstring-array지정한 DMA 채널의 이름입니다.
io-channelsphandle-arrayI/O 채널을 지정하는 phandle 배열입니다.
io-channel-namesstring-array지정한 I/O 채널의 이름입니다.
mboxesphandle-array메일박스/IPM 채널을 지정하는 phandle 배열입니다.
mbox-namesstring-array지정한 메일박스/IPM 채널의 이름입니다.
zephyr,deferred-initboolean부팅할 때 장치를 자동으로 초기화하지 않습니다. 이후 device_init()를 호출해 직접 초기화해야 합니다.

Source