.. SPDX-License-Identifier: GPL-2.0
=========================================================
Neterion's (Formerly S2io) Xframe I/II PCI-X 10GbE driver
=========================================================
Release notes for Neterion's (Formerly S2io) Xframe I/II PCI-X 10GbE driver.
.. Contents
- 1. Introduction
- 2. Identifying the adapter/interface
- 3. Features supported
- 4. Command line parameters
- 5. Performance suggestions
- 6. Available Downloads
1. Introduction
===============
This Linux driver supports Neterion's Xframe I PCI-X 1.0 and
Xframe II PCI-X 2.0 adapters. It supports several features
such as jumbo frames, MSI/MSI-X, checksum offloads, TSO, UFO and so on.
See below for complete list of features.
All features are supported for both IPv4 and IPv6.
2. Identifying the adapter/interface
====================================
a. Insert the adapter(s) in your system.
b. Build and load driver::
# insmod s2io.ko
c. View log messages::
# dmesg | tail -40
You will see messages similar to::
eth3: Neterion Xframe I 10GbE adapter (rev 3), Version 2.0.9.1, Intr type INTA
eth4: Neterion Xframe II 10GbE adapter (rev 2), Version 2.0.9.1, Intr type INTA
eth4: Device is on 64 bit 133MHz PCIX(M1) bus
The above messages identify the adapter type(Xframe I/II), adapter revision,
driver version, interface name(eth3, eth4), Interrupt type(INTA, MSI, MSI-X).
In case of Xframe II, the PCI/PCI-X bus width and frequency are displayed
as well.
To associate an interface with a physical adapter use "ethtool -p <ethX>".
The corresponding adapter's LED will blink multiple times.
3. Features supported
=====================
a. Jumbo frames. Xframe I/II supports MTU up to 9600 bytes,
modifiable using ip command.
b. Offloads. Supports checksum offload(TCP/UDP/IP) on transmit
and receive, TSO.
c. Multi-buffer receive mode. Scattering of packet across multiple
buffers. Currently driver supports 2-buffer mode which yields
significant performance improvement on certain platforms(SGI Altix,
IBM xSeries).
d. MSI/MSI-X. Can be enabled on platforms which support this feature
resulting in noticeable performance improvement (up to 7% on certain
platforms).
e. Statistics. Comprehensive MAC-level and software statistics displayed
using "ethtool -S" option.
f. Multi-FIFO/Ring. Supports up to 8 transmit queues and receive rings,
with multiple steering options.
4. Command line parameters
==========================
a. tx_fifo_num
Number of transmit queues
Valid range: 1-8
Default: 1
b. rx_ring_num
Number of receive rings
Valid range: 1-8
Default: 1
c. tx_fifo_len
Size of each transmit queue
Valid range: Total length of all queues should not exceed 8192
Default: 4096
d. rx_ring_sz
Size of each receive ring(in 4K blocks)
Valid range: Limited by memory on system
Default: 30
e. intr_type
Specifies interrupt type. Possible values 0(INTA), 2(MSI-X)
Valid values: 0, 2
Default: 2
5. Performance suggestions
==========================
General:
a. Set MTU to maximum(9000 for switch setup, 9600 in back-to-back configuration)
b. Set TCP windows size to optimal value.
For instance, for MTU=1500 a value of 210K has been observed to result in
good performance::
# sysctl -w net.ipv4.tcp_rmem="210000 210000 210000"
# sysctl -w net.ipv4.tcp_wmem="210000 210000 210000"
For MTU=9000, TCP window size of 10 MB is recommended::
# sysctl -w net.ipv4.tcp_rmem="10000000 10000000 10000000"
# sysctl -w net.ipv4.tcp_wmem="10000000 10000000 10000000"
Transmit performance:
a. By default, the driver respects BIOS settings for PCI bus parameters.
However, you may want to experiment with PCI bus parameters
max-split-transactions(MOST) and MMRBC (use setpci command).
A MOST value of 2 has been found optimal for Opterons and 3 for Itanium.
It could be different for your hardware.
Set MMRBC to 4K**.
For example you can set
For opteron::
#setpci -d 17d5:* 62=1d
For Itanium::
#setpci -d 17d5:* 62=3d
For detailed description of the PCI registers, please see Xframe User Guide.
b. Ensure Transmit Checksum offload is enabled. Use ethtool to set/verify this
parameter.
c. Turn on TSO(using "ethtool -K")::
# ethtool -K <ethX> tso on
Receive performance:
a. By default, the driver respects BIOS settings for PCI bus parameters.
However, you may want to set PCI latency timer to 248::
#setpci -d 17d5:* LATENCY_TIMER=f8
For detailed description of the PCI registers, please see Xframe User Guide.
b. Use 2-buffer mode. This results in large performance boost on
certain platforms(eg. SGI Altix, IBM xSeries).
c. Ensure Receive Checksum offload is enabled. Use "ethtool -K ethX" command to
set/verify this option.
d. Enable NAPI feature(in kernel configuration Device Drivers ---> Network
device support ---> Ethernet (10000 Mbit) ---> S2IO 10Gbe Xframe NIC) to
bring down CPU utilization.
.. note::
For AMD opteron platforms with 8131 chipset, MMRBC=1 and MOST=1 are
recommended as safe parameters.
For more information, please review the AMD8131 errata at
http://vip.amd.com/us-en/assets/content_type/white_papers_and_tech_docs/
26310_AMD-8131_HyperTransport_PCI-X_Tunnel_Revision_Guide_rev_3_18.pdf
6. Support
==========
For further support please contact either your 10GbE Xframe NIC vendor (IBM,
HP, SGI etc.)
3. 한국어 전문 번역
영어 원문의 문단 순서와 의미를 유지한 전체 번역입니다. 코드, 함수명, symbol과 URL은 원문 표기를 유지합니다.
드라이버 개요, 식별과 기능
1-75이 문서는 `GPL-2.0` 라이선스를 따릅니다.
Neterion(구 S2io) Xframe I/II PCI-X 10GbE 드라이버
이 Linux 드라이버는 Xframe I PCI-X 1.0과 Xframe II PCI-X 2.0 어댑터를 지원합니다. jumbo frame, MSI/MSI-X, checksum offload, TSO, UFO 등을 IPv4와 IPv6 모두에서 제공합니다.
어댑터와 인터페이스 식별
- 어댑터를 시스템에 장착합니다.
- `s2io.ko`를 빌드해 로드합니다.
- 최근 커널 로그를 확인합니다.
# insmod s2io.ko
# dmesg | tail -40
로그는 다음과 비슷합니다.
eth3: Neterion Xframe I 10GbE adapter (rev 3), Version 2.0.9.1, Intr type INTA
eth4: Neterion Xframe II 10GbE adapter (rev 2), Version 2.0.9.1, Intr type INTA
eth4: Device is on 64 bit 133MHz PCIX(M1) bus
메시지에서 Xframe I/II 유형, revision, driver version, interface name과 interrupt type(INTA, MSI, MSI-X)을 확인합니다. Xframe II는 PCI/PCI-X bus width와 frequency도 표시합니다. `ethtool -p <ethX>`를 실행하면 대응 어댑터의 LED가 여러 번 깜박입니다.
원문의 기능 목록과 한계를 정리했습니다.
.. SPDX-License-Identifier: GPL-2.0
=========================================================
Neterion's (Formerly S2io) Xframe I/II PCI-X 10GbE driver
=========================================================
Release notes for Neterion's (Formerly S2io) Xframe I/II PCI-X 10GbE driver.
.. Contents
- 1. Introduction
- 2. Identifying the adapter/interface
- 3. Features supported
- 4. Command line parameters
- 5. Performance suggestions
- 6. Available Downloads
1. Introduction
===============
This Linux driver supports Neterion's Xframe I PCI-X 1.0 and
Xframe II PCI-X 2.0 adapters. It supports several features
such as jumbo frames, MSI/MSI-X, checksum offloads, TSO, UFO and so on.
See below for complete list of features.
All features are supported for both IPv4 and IPv6.
2. Identifying the adapter/interface
====================================
a. Insert the adapter(s) in your system.
b. Build and load driver::
# insmod s2io.ko
c. View log messages::
# dmesg | tail -40
You will see messages similar to::
eth3: Neterion Xframe I 10GbE adapter (rev 3), Version 2.0.9.1, Intr type INTA
eth4: Neterion Xframe II 10GbE adapter (rev 2), Version 2.0.9.1, Intr type INTA
eth4: Device is on 64 bit 133MHz PCIX(M1) bus
The above messages identify the adapter type(Xframe I/II), adapter revision,
driver version, interface name(eth3, eth4), Interrupt type(INTA, MSI, MSI-X).
In case of Xframe II, the PCI/PCI-X bus width and frequency are displayed
as well.
To associate an interface with a physical adapter use "ethtool -p <ethX>".
The corresponding adapter's LED will blink multiple times.
3. Features supported
=====================
a. Jumbo frames. Xframe I/II supports MTU up to 9600 bytes,
modifiable using ip command.
b. Offloads. Supports checksum offload(TCP/UDP/IP) on transmit
and receive, TSO.
c. Multi-buffer receive mode. Scattering of packet across multiple
buffers. Currently driver supports 2-buffer mode which yields
significant performance improvement on certain platforms(SGI Altix,
IBM xSeries).
d. MSI/MSI-X. Can be enabled on platforms which support this feature
resulting in noticeable performance improvement (up to 7% on certain
platforms).
e. Statistics. Comprehensive MAC-level and software statistics displayed
using "ethtool -S" option.
f. Multi-FIFO/Ring. Supports up to 8 transmit queues and receive rings,
with multiple steering options.
명령줄 매개변수
76-113명령줄 매개변수
유효 범위와 기본값을 원문 그대로 보존했습니다.
4. Command line parameters
==========================
a. tx_fifo_num
Number of transmit queues
Valid range: 1-8
Default: 1
b. rx_ring_num
Number of receive rings
Valid range: 1-8
Default: 1
c. tx_fifo_len
Size of each transmit queue
Valid range: Total length of all queues should not exceed 8192
Default: 4096
d. rx_ring_sz
Size of each receive ring(in 4K blocks)
Valid range: Limited by memory on system
Default: 30
e. intr_type
Specifies interrupt type. Possible values 0(INTA), 2(MSI-X)
Valid values: 0, 2
Default: 2
성능 권장 사항과 지원
114-196성능 권장 사항
일반적으로 MTU를 최대로 설정합니다. switch 구성은 9000, 직접 연결(back-to-back)은 9600을 사용하고 TCP window를 알맞게 조정합니다.
MTU 1500에서는 210 KiB가 좋은 결과를 보인 예가 있습니다.
# sysctl -w net.ipv4.tcp_rmem="210000 210000 210000"
# sysctl -w net.ipv4.tcp_wmem="210000 210000 210000"
MTU 9000에서는 TCP window 10 MB를 권장합니다.
# sysctl -w net.ipv4.tcp_rmem="10000000 10000000 10000000"
# sysctl -w net.ipv4.tcp_wmem="10000000 10000000 10000000"
송신 성능
- 기본적으로 PCI bus parameter의 BIOS 설정을 따릅니다. 필요하면 `setpci`로 max-split-transactions(MOST)와 MMRBC를 실험할 수 있습니다.
- 관측된 최적 MOST 값은 Opteron에서 2, Itanium에서 3이지만 하드웨어마다 다를 수 있습니다.
- MMRBC는 4K로 설정합니다.
- TX checksum offload가 켜져 있는지 ethtool로 확인합니다.
- `ethtool -K`로 TSO를 켭니다.
#setpci -d 17d5:* 62=1d
#setpci -d 17d5:* 62=3d
# ethtool -K <ethX> tso on
수신 성능
- 필요하면 PCI latency timer를 248(`f8`)로 설정합니다.
- 일부 SGI Altix와 IBM xSeries 플랫폼에서 큰 향상을 주는 2-buffer mode를 사용합니다.
- `ethtool -K ethX`로 RX checksum offload가 켜졌는지 확인합니다.
- 커널 구성의 S2IO 10GbE Xframe NIC에서 NAPI를 활성화해 CPU 사용량을 낮춥니다.
#setpci -d 17d5:* LATENCY_TIMER=f8
AMD Opteron과 8131 chipset 조합에서는 안전한 값으로 MMRBC=1, MOST=1을 권장합니다. 자세한 내용은 원문의 AMD8131 errata 링크를 참고하십시오.
추가 지원은 IBM, HP, SGI 등 사용 중인 10GbE Xframe NIC 공급업체에 문의하십시오.
5. Performance suggestions
==========================
General:
a. Set MTU to maximum(9000 for switch setup, 9600 in back-to-back configuration)
b. Set TCP windows size to optimal value.
For instance, for MTU=1500 a value of 210K has been observed to result in
good performance::
# sysctl -w net.ipv4.tcp_rmem="210000 210000 210000"
# sysctl -w net.ipv4.tcp_wmem="210000 210000 210000"
For MTU=9000, TCP window size of 10 MB is recommended::
# sysctl -w net.ipv4.tcp_rmem="10000000 10000000 10000000"
# sysctl -w net.ipv4.tcp_wmem="10000000 10000000 10000000"
Transmit performance:
a. By default, the driver respects BIOS settings for PCI bus parameters.
However, you may want to experiment with PCI bus parameters
max-split-transactions(MOST) and MMRBC (use setpci command).
A MOST value of 2 has been found optimal for Opterons and 3 for Itanium.
It could be different for your hardware.
Set MMRBC to 4K**.
For example you can set
For opteron::
#setpci -d 17d5:* 62=1d
For Itanium::
#setpci -d 17d5:* 62=3d
For detailed description of the PCI registers, please see Xframe User Guide.
b. Ensure Transmit Checksum offload is enabled. Use ethtool to set/verify this
parameter.
c. Turn on TSO(using "ethtool -K")::
# ethtool -K <ethX> tso on
Receive performance:
a. By default, the driver respects BIOS settings for PCI bus parameters.
However, you may want to set PCI latency timer to 248::
#setpci -d 17d5:* LATENCY_TIMER=f8
For detailed description of the PCI registers, please see Xframe User Guide.
b. Use 2-buffer mode. This results in large performance boost on
certain platforms(eg. SGI Altix, IBM xSeries).
c. Ensure Receive Checksum offload is enabled. Use "ethtool -K ethX" command to
set/verify this option.
d. Enable NAPI feature(in kernel configuration Device Drivers ---> Network
device support ---> Ethernet (10000 Mbit) ---> S2IO 10Gbe Xframe NIC) to
bring down CPU utilization.
.. note::
For AMD opteron platforms with 8131 chipset, MMRBC=1 and MOST=1 are
recommended as safe parameters.
For more information, please review the AMD8131 errata at
http://vip.amd.com/us-en/assets/content_type/white_papers_and_tech_docs/
26310_AMD-8131_HyperTransport_PCI-X_Tunnel_Revision_Guide_rev_3_18.pdf
6. Support
==========
For further support please contact either your 10GbE Xframe NIC vendor (IBM,
HP, SGI etc.)
요약·해설
s2io.rst:1-196이 문서는 오래된 PCI-X 10GbE 어댑터를 다루므로 일반 네트워크 튜닝뿐 아니라 bus transaction 설정이 성능에 큰 영향을 줍니다. 먼저 MTU, TCP window, checksum/TSO와 NAPI를 맞춘 뒤 플랫폼별 MOST/MMRBC를 시험해야 합니다.
위험이 낮은 설정부터 플랫폼별 PCI-X 조정으로 진행합니다.